Independent archive written from public records. It is not run by BE-ST (formerly the Construction Scotland Innovation Centre), Construction Scotland or Edinburgh Napier University, and does not speak for them.
CSIC ArchiveIndependent notes on construction innovation in Scotland, 2014–2022

EPC rating explained: what the A to G bands mean and how the score is calculated

Published 2026-11-26

An Energy Performance Certificate gives a building a letter from A to G, and that letter now follows a home everywhere: in the estate agent's listing, the mortgage file, the landlord's compliance folder and government targets for the housing stock. Few people know what the letter actually measures. This guide explains the score behind it, the thresholds for each band, and how the certificate is produced and read in Scotland.

What the rating measures

The headline figure on a domestic EPC is the energy efficiency rating. It is calculated with the Standard Assessment Procedure (SAP), the UK government's method for assessing the energy performance of dwellings. Despite its name, the rating is a measure of running cost: according to the SAP 10.2 specification published by BRE, it is based on the energy costs of space heating, water heating, ventilation and lighting, minus savings from energy generated on site, and adjusted for floor area so that it is essentially independent of the size of the home. It is expressed on a scale of 1 to 100, the higher the number the lower the running costs, and it can exceed 100 when a home generates more energy than it uses.

A second scale sits next to it on the certificate: the environmental impact rating, based on the home's annual carbon dioxide emissions, again adjusted for floor area. The two usually move together, but not always. A home heated by an electric system can score well on emissions and less well on cost, or the reverse, depending on fuel prices and carbon factors used in the methodology.

The bands: from G to A

The specification assigns each score to a band, and the same table applies to both ratings. It is the reason why a single point can move a home from one letter to the next: a score of 68 is a D, a score of 69 a C.

SAP scoreBandWhat it usually means in practice
92 or moreAVery low running costs; typically new, highly insulated homes with low-carbon heating and on-site generation.
81 to 91BMost homes built to recent building standards.
69 to 80CA well-insulated older home with efficient heating; the band most policy targets aim for.
55 to 68DTypical of the existing housing stock, with some insulation and a gas boiler.
39 to 54EOlder homes with limited insulation or expensive heating.
21 to 38FSolid-walled or poorly insulated homes, often with electric storage or oil heating.
1 to 20GThe least efficient homes, with very high running costs for their size.

The right-hand column is a general guide, not part of the methodology: two homes in the same band can be very different buildings.

How the score is calculated

SAP works out an annual energy cost for the home under standard conditions: a standard occupancy, a standard heating pattern and UK average weather. It does not use the bills of the people living there. The total cost is divided by the floor area plus a fixed allowance, then converted into the 1 to 100 scale with a logarithmic formula. Two consequences follow. A larger home is not penalised for its size, and changes in the fuel prices written into the methodology can move ratings even when nothing has been done to the building.

New homes are assessed with the full SAP calculation, using the designer's drawings and specifications; the same calculation shows compliance with the energy standards at building warrant stage. Existing homes are usually assessed with reduced data SAP (RdSAP). According to the UK government's page on the Standard Assessment Procedure, SAP was first published in 1993 and adopted as the methodology behind Energy Performance Certificates in 2007, while RdSAP was introduced in 2005 as a simpler and lower cost method that relies on a set of assumptions about the dwelling. The same page gives the current versions as SAP 10.3 and RdSAP 10.0.1.

Those assumptions matter. If the assessor cannot see wall insulation or confirm the thickness of loft insulation, RdSAP uses default values based on the age and type of the building. Keeping invoices and certificates for insulation, windows and heating work, and showing them to the assessor, is the simplest way to avoid a rating that is lower than the home deserves.

Reading a Scottish EPC

A domestic certificate shows the two ratings as coloured bar charts, with the current score and the potential score if the recommended measures were carried out. It lists the main elements of the building (walls, roof, floor, windows, heating, hot water and lighting) with a short performance description for each, estimated energy use and costs, and a list of recommended improvements with indicative costs.

Under the Energy Performance of Buildings (Scotland) Regulations 2008, a valid certificate must be available when a home is offered for sale or let and handed over when a new building is completed. The GOV.UK guide to Energy Performance Certificates notes that a certificate is valid for 10 years and that, in Scotland, it must be displayed somewhere in the property, for example in the meter cupboard or next to the boiler. Certificates are lodged on the Scottish EPC Register, where anyone can retrieve one by postcode or report reference number.

Moving up a band

Because the rating is cost-based and adjusted for floor area, the measures that move it most are those that cut the modelled cost of heating the whole home: loft and wall insulation, draught-proofing, efficient heating controls, replacing an old boiler or electric storage heaters, and adding solar panels. The recommendations on the certificate are listed in the order the methodology considers most cost-effective, with the score expected after each step. They are a starting point, not a renovation plan; for older and traditional buildings, moisture and ventilation need to be considered before insulating walls.

For new homes, the New Build Heat Standard already rules out direct-emission heating such as gas boilers in most buildings applying for a warrant from April 2024, which pushes new homes towards heat pumps and heat networks.

What changes in 2028

Scotland has legislated for a new certificate that will replace the single headline letter with three separate ratings for homes: heat retention, heating system and energy cost. The switch, originally due in October 2026, has been delayed to April 2028, and new certificates will be valid for five years instead of ten. Our article on Scotland's EPC reform explains what the new indicators will show and what stays the same until then. Until the switch, every certificate in Scotland is produced with the SAP and RdSAP methods described above, and the A to G thresholds in this guide continue to apply.

Sources